Product Overview
Animal husbandry and industrial multi-purpose fans currently include axial flow fans and negative pressure fans. Stainless steel/FRP materials and other different specifications can be customized according to customer requirements.
Product Advantages
This fan has the characteristics of simple structure, low noise, easy installation, good anti-corrosion performance, high static pressure and efficiency, stable operation, and small mechanical vibration.
Application
Widely used in pig houses, farms, industrial and mining enterprises, warehouses, offices, residences and other places for ventilation. It is also suitable for use in pickling sections, laboratories, basements, power plants, electroplating, oxidation plants and other places containing corrosive gases. It can also be installed in series at intervals in long pipelines to increase the pressure in the pipeline.
Working Principle of Negative Pressure Fan
The negative pressure fan uses the cooling principle of air convection and negative pressure ventilation. It is a kind of natural intake of fresh air from the opposite side of the installation site — the door or window, and the indoor stuffy air is quickly forced out of the room. The machine can improve any poor ventilation problems, and the cooling and ventilation effect can reach 90%-97%.

Schematic Diagram of Negative Pressure Fan Assembly

EC/AC Motor Efficiency Comparison
As shown in the figure below: there is basically no difference between the two motors before the torque is 5N.M. After the torque is 5N.M, especially when the torque reaches 10N.M~40N.M, the efficiency of the EC motor reaches 80%-90%, while the efficiency of the AC motor is 70%~80% only. When it is above 40N.M, the EC motor maintains a high efficiency of 90%, while the efficiency of the AC motor drops significantly to 40%. In summary, the EC motor has higher torque and higher efficiency than the AC motor.
Advantages of EC Motor
Operation Analysis
EC motor
- The starting current is small and stable, and the best working efficiency point can be reached at full power and full speed.
- Built-in overload, undervoltage and overvoltage protection functions.
- The motor itself is energy-saving, and at the same time, it is self-adapting (self-matching) when the fan is running, so as to adapt to various working conditions and use environments for secondary energy saving, achieving double energy saving.
AC motor
- The starting current is large, and the current has a great impact on the motor itself, which will also affect the service life of the motor. At the same time, it consumes a lot of energy, and the starting energy consumption is 20-30 times that of the EC motor.
- No overload, no speed adjustment (speed adjustment needs to add the frequency converter), and the efficiency of the motor is lower when the speed is adjusted.
- After starting, the rotor needs to establish a magnetic field to consume too much power.
Assembly Cost Analysis
EC Motor
- 3 phases 380V 1.1kw EC Motor – $285
- Controller – $16
- Air switch – $6
- Simple wiring – $5
- Total – $310
AC Motor
- 3 phases 380V 1.1KW AC motor – $85
- Frequency converter 1.1KW – $160
- Air switch – $6
- Electric box assembly 10-way per set – $12
- AC contactor – $10
- Overload protector – $16
- Phase sequence protector – $12
- Complex wirings – $300 (More than 30 wirings, labor $100/day, 10-way control electric box, construction period 3 days, a total of $300.)
- Total – $601
Analysis of Motor Efficiency
*Under different speed conditions:
Conclusion: With the speed change of EC motor, the proportion of energy saving gradually increases!
*Under different voltage conditions:

Conclusion: With the voltage change of EC motor, the proportion of energy saving gradually increases!
Fan Efficiency Analysis

Conclusion: under working conditions of different static pressure, the comprehensive energy-saving 450 fan reaches 10.39%, 550 fan reaches 9.54%, 710 fan reaches 9.48%, 910 fan reaches 7.77%
Electricity Cost Analysis


TOTAL COST ANALYSIS
That’s why I RECOMMEND you use EC motor fan.